Repository logo
 
Publication

Influence of a SVC on AC Arc furnaces harmonics, flicker and unbalance. Measurement and analysis.

datacite.subject.fosEngenharia e Tecnologia::Engenharia Eletrotécnica, Eletrónica e Informática
datacite.subject.sdg07:Energias Renováveis e Acessíveis
datacite.subject.sdg09:Indústria, Inovação e Infraestruturas
datacite.subject.sdg11:Cidades e Comunidades Sustentáveis
dc.contributor.authorDonsión, M. P.
dc.contributor.authorGüemes, J. A.
dc.contributor.authorOliveira, F.
dc.date.accessioned2025-11-11T16:39:29Z
dc.date.available2025-11-11T16:39:29Z
dc.date.issued2010-04
dc.descriptionFonte: https://www.researchgate.net/publication/224142751_Influence_of_a_SVC_on_AC_Arc_Furnaces_Harmonics_Flicker_and_Unbalance_Measurement_and_analysis
dc.descriptionArticle number - 5476032; Conference name - 15th IEEE Mediterranean Electrotechnical Conference, MELECON 2010; Conference date - 25 April 2010 - 28 April 2010; Conference code - 80899
dc.descriptionEISBN - 978-1-4244-5795-3
dc.description.abstractAn AC arc furnace is an unbalanced, nonlinear and time varying load, which can cause many problems to power system quality. Different studies on arc furnaces harmonics analysis can be found in the bibliography on the topic; however, it is very difficult obtain an exact model that takes into account all the parameters that have influence on the process, therefore it is necessary to take measurements under different conditions. In this paper we'll present the harmonic distortion, flicker and unbalance results and conclusions on three different measurement campaigns in an iron and steel industry (SNL) with an AC arc furnace of 83 MW (170 TM) with a transformer of 120 MVA connected with a dedicated power line of 220 kV (55 km) to the Carregado Substation, where there are another other branches that connect industrial and domestic consumers.eng
dc.description.sponsorshipThe authors wish to thank the support from the Spanish “Ministerio de Ciencia y Tecnología” , Research Project: ENE2007-6803-C04-01.
dc.identifier.citationM. P. Donsión, J. A. Güemes and F. Oliveira, "Influence of a SVC on AC Arc furnaces harmonics, flicker and unbalance measurement and analysis," Melecon 2010 - 2010 15th IEEE Mediterranean Electrotechnical Conference, Valletta, Malta, 2010, pp. 1423-1428, doi: https://doi.org/10.1109/MELCON.2010.5476032.
dc.identifier.doi10.1109/melcon.2010.5476032
dc.identifier.eissn2158-8481
dc.identifier.isbn978-1-4244-5793-9
dc.identifier.isbn978-1-4244-5795-3
dc.identifier.issn2158-8473
dc.identifier.urihttp://hdl.handle.net/10400.8/14591
dc.language.isoeng
dc.peerreviewedyes
dc.publisherIEEE Canada
dc.relation.hasversionhttps://ieeexplore.ieee.org/document/5476032
dc.relation.ispartofMelecon 2010 - 2010 15th IEEE Mediterranean Electrotechnical Conference
dc.rights.uriN/A
dc.subjectFlicker
dc.subjectharmonics
dc.subjectpower quality
dc.subjectelectric power measurements
dc.subjectarc furnaces
dc.titleInfluence of a SVC on AC Arc furnaces harmonics, flicker and unbalance. Measurement and analysis.eng
dc.typeconference paper
dspace.entity.typePublication
oaire.citation.conferenceDate2010-04
oaire.citation.conferencePlaceValletta, Malta
oaire.citation.endPage1428
oaire.citation.startPage1423
oaire.citation.titleProceedings of the Mediterranean Electrotechnical Conference - MELECON
oaire.versionhttp://purl.org/coar/version/c_970fb48d4fbd8a85
person.familyNameOliveira
person.givenNameFilipe Tadeu
person.identifier.ciencia-id5A17-E4E1-C004
person.identifier.gsidmIvAC50AAAAJ
person.identifier.orcid0000-0002-0410-4291
person.identifier.ridH-8020-2012
person.identifier.scopus-author-id57188647924
relation.isAuthorOfPublicationf3c004bf-5759-4b8c-87c8-350bd598d035
relation.isAuthorOfPublication.latestForDiscoveryf3c004bf-5759-4b8c-87c8-350bd598d035

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Influence of a SVC on AC arc furnaces harmonics, flicker and unbalance. Measurement and analysis..pdf
Size:
638.86 KB
Format:
Adobe Portable Document Format
Description:
An AC arc furnace is an unbalanced, nonlinear and time varying load, which can cause many problems to power system quality. Different studies on arc furnaces harmonics analysis can be found in the bibliography on the topic; however, it is very difficult obtain an exact model that takes into account all the parameters that have influence on the process, therefore it is necessary to take measurements under different conditions. In this paper we'll present the harmonic distortion, flicker and unbalance results and conclusions on three different measurement campaigns in an iron and steel industry (SNL) with an AC arc furnace of 83 MW (170 TM) with a transformer of 120 MVA connected with a dedicated power line of 220 kV (55 km) to the Carregado Substation, where there are another other branches that connect industrial and domestic consumers.
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.32 KB
Format:
Item-specific license agreed upon to submission
Description: