Repository logo
 
Publication

Experimental evaluation of energy dissipation and viscous damping of repaired and strengthened RC columns with CFRP jacketing under biaxial load

dc.contributor.authorRodriges, H.
dc.contributor.authorFurtado, André
dc.contributor.authorArêde, António
dc.date.accessioned2025-05-14T09:48:31Z
dc.date.available2025-05-14T09:48:31Z
dc.date.issued2017-05-18
dc.description.abstractThe seismic repair and retrofitting of reinforced concrete (RC) columns have been the focus of innumerous studies and from the literature it can be concluded that the biaxial horizontal loading can reduce considerably the strength capacity, ductility and energy dissipation of the columns when compared with the corresponding response to uniaxial loading tests. However, reduced information regarding the influence of the retrofit strategies in the energy dissipation capacity and the viscous damping of the columns were obtained. Thus the main goal of the present work is to evaluate the efficiency of the Carbon Fiber Reinforced Polymer (CFRP) jacketing technique to improve the behaviour of three damaged columns subjected to repair procedures and four ‘‘as built” columns behaviour and evaluate their influence in the energy dissipation capacity and viscous damping of the columns when compared with the original response. From the test results a good efficiency of the CFRP jacketing improved about 20% the original energy dissipation capacity. Regarding the viscous damping it was obtained about 10% lower values for the repaired columns and to 20% higher values for the strengthened ones.eng
dc.identifier.citationHugo Rodrigues, André Furtado, António Arêde, Experimental evaluation of energy dissipation and viscous damping of repaired and strengthened RC columns with CFRP jacketing under biaxial load, Engineering Structures, Volume 145, 2017, Pages 162-175, ISSN 0141-0296, https://doi.org/10.1016/j.engstruct.2017.05.021.
dc.identifier.doi10.1016/j.engstruct.2017.05.021
dc.identifier.issn0141-0296
dc.identifier.urihttp://hdl.handle.net/10400.8/12876
dc.language.isoeng
dc.peerreviewedyes
dc.publisherElsevier
dc.relation.hasversionhttps://www.sciencedirect.com/science/article/pii/S0141029617315924?via%3Dihub
dc.rights.uriN/A
dc.subjectRC strengthened columns
dc.subjectRC repaired columns
dc.subjectCFRP jacketing
dc.subjectEnergy dissipation
dc.subjectDamping
dc.titleExperimental evaluation of energy dissipation and viscous damping of repaired and strengthened RC columns with CFRP jacketing under biaxial loadeng
dc.typeresearch article
dspace.entity.typePublication
oaire.citation.endPage175
oaire.citation.startPage162
oaire.citation.titleEngineering Structures
oaire.citation.volume145
oaire.versionhttp://purl.org/coar/version/c_970fb48d4fbd8a85

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
1-s2.0-S0141029617315924-main.pdf
Size:
2.67 MB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.32 KB
Format:
Item-specific license agreed upon to submission
Description: