Publication
Reliability and validity of the international physical activity questionnaire short-form (IPAQ-sf) in COPD
dc.contributor.author | Flora, Sofia | |
dc.contributor.author | Hipólito, Nádia | |
dc.contributor.author | Santos, Liliana | |
dc.contributor.author | Januário, Filipa | |
dc.contributor.author | Silva, Sónia | |
dc.contributor.author | Valente, Carla | |
dc.contributor.author | Andrade, L | |
dc.contributor.author | Rodrigues, Fátima | |
dc.contributor.author | Marques, Alda | |
dc.contributor.author | Cruz, Joana | |
dc.date.accessioned | 2022-05-06T09:44:17Z | |
dc.date.available | 2022-05-06T09:44:17Z | |
dc.date.issued | 2020 | |
dc.description.abstract | Physical activity (PA) may improve COPD prognosis, thus its assessment and promotion are crucial. The International Physical Activity Questionnaire Short-Form (IPAQ-sf) is widely used for assessing PA but there is limited evidence on its clinimetric properties in COPD. We assessed the test-retest reliability and validity of the IPAQ-sf in patients with COPD. Fifty-five participants (68.6±7.8yrs, 48 males, FEV1 52.3±22.5%pred) completed the IPAQ-sf, wore an accelerometer for 7 days and completed a second IPAQ-sf. Test-retest reliability/agreement was assessed with: Intraclass Correlation (ICC, 95%CI), 95% Limits of Agreement (LoA), standard error of measurement (SEM) and minimal detectable change (MDC95) for continuous variables; %agreement for categories (“active” vs “inactive”). Validity was assessed with Spearman’s correlations (ρ) between the IPAQ-sf (METs-min/week, time in vigorous [VPA] and moderate PA [MPA] per week) and accelerometry [time in MVPA, VPA and MPA per week] for continuous variables; %agreement, Cohen’s kappa, sensitivity and specificity (95%CI) for categories. Reliability was acceptable (ICC=0.738, 0.629→0.873) but with wide LoA (-5713→4793.3 METs-min/week). SEM and MDC95 were 1844.7 and 5113.3 METs-min/week, respectively. %agreement of the two IPAQ-sf was 85.5% (kappa=0.660, 0.444→0.876). Significant correlations were found between METsmin/week and accelerometry (0.515≤ρ≤0.596), except for VPA (p>0.05). %agreement between tools was 67.3% (kappa=0.350, 0.279→0.571) with high sensitivity (0.89, 0.887→0.891) but low specificity (0.46, 0.46→0.47). The IPAQ-sf could be used as PA measurement tool in COPD although caution is needed to avoid misclassification. | pt_PT |
dc.description.version | info:eu-repo/semantics/publishedVersion | pt_PT |
dc.identifier.citation | European Respiratory Journal 2020; 56: Suppl. 64, 253. | pt_PT |
dc.identifier.doi | 10.1183/13993003.congress-2020.253 | pt_PT |
dc.identifier.eissn | 1399-3003 | |
dc.identifier.uri | http://hdl.handle.net/10400.8/7112 | |
dc.language.iso | eng | pt_PT |
dc.peerreviewed | yes | pt_PT |
dc.publisher | ERS - European Respiratory Society | pt_PT |
dc.relation.ispartofseries | Suppl 64; | |
dc.subject | COPD | pt_PT |
dc.subject | Physical activity | pt_PT |
dc.subject | Quality of life | pt_PT |
dc.title | Reliability and validity of the international physical activity questionnaire short-form (IPAQ-sf) in COPD | pt_PT |
dc.type | journal article | |
dspace.entity.type | Publication | |
oaire.citation.startPage | 253 | pt_PT |
oaire.citation.title | European Respiratory Journal | pt_PT |
oaire.citation.volume | 56 | pt_PT |
person.familyName | Flora | |
person.familyName | Hipólito | |
person.familyName | de Almeida Andrade | |
person.familyName | Marques | |
person.familyName | Cruz | |
person.givenName | Sofia | |
person.givenName | Nádia | |
person.givenName | Maria Lília | |
person.givenName | Alda | |
person.givenName | Joana | |
person.identifier.ciencia-id | 551E-FBBD-E7ED | |
person.identifier.ciencia-id | 161D-76B4-3740 | |
person.identifier.ciencia-id | DD1B-7FC7-7981 | |
person.identifier.ciencia-id | DE15-EFBA-4856 | |
person.identifier.ciencia-id | E213-7D20-5C3C | |
person.identifier.orcid | 0000-0002-2365-0431 | |
person.identifier.orcid | 0000-0003-1796-6218 | |
person.identifier.orcid | 0000-0003-2258-0643 | |
person.identifier.orcid | 0000-0003-4980-6200 | |
person.identifier.orcid | 0000-0002-4911-4469 | |
person.identifier.rid | K-7030-2013 | |
person.identifier.scopus-author-id | 36715922000 | |
rcaap.rights | openAccess | pt_PT |
rcaap.type | article | pt_PT |
relation.isAuthorOfPublication | cd0b7812-5f37-4baa-845c-e46d6b7b404b | |
relation.isAuthorOfPublication | 19bb0257-324b-4231-8fcb-b4b5655427c6 | |
relation.isAuthorOfPublication | 0e74691e-bc90-4a4a-a8ee-9dff70a0f132 | |
relation.isAuthorOfPublication | 2b4618ae-9c47-4033-94ea-24c9793d73e7 | |
relation.isAuthorOfPublication | 33428074-748a-4751-b2f7-9f24247715fd | |
relation.isAuthorOfPublication.latestForDiscovery | 0e74691e-bc90-4a4a-a8ee-9dff70a0f132 |
Files
Original bundle
1 - 1 of 1
Loading...
- Name:
- 2020_Flora_Reliability_and_validity_ERS.pdf
- Size:
- 193.47 KB
- Format:
- Adobe Portable Document Format
- Description: