Repository logo
 
Publication

The Reliability of the Timed Up and Go Test among Portuguese Elderly

dc.contributor.authorRodrigues, Filipe
dc.contributor.authorTeixeira, José
dc.contributor.authorForte, Pedro
dc.date.accessioned2024-09-03T10:24:40Z
dc.date.available2024-09-03T10:24:40Z
dc.date.issued2023-03-23
dc.description.abstractAssessment of dynamic balance is typically completed through functional tests, such as the Timed Up and Go (TUG) test, which measures the time it takes for an individual to stand up from a chair, walk a set distance, turn around, and sit back down. This test has been validated in several countries. However, in the Portuguese population there is a gap on testing the reliability of this functional test in a sample of the elderly both living in the community or in nursing homes. Thus, this study aimed at examining the reliability of the TUG in a sample of Portuguese elderly. An Intraclass Correlation Coefficient (ICC) analysis was performed between the first time (T1) and the time score after 16 weeks (T2) in TUG test by 38 males and 79 females aged between 60 and 92 years. The results showed acceptable scores of ICC in community-dwelling and nursing home resident elderly in both moments. In addition, significant differences were found between these groups of older adults, showing that community-dwelling elderly show greater agility and balance capacity compared to those living in nursing homes. Thus, the TUG test can be applied in the Portuguese elderly in both community-dwelling and nursing home resident elderly.pt_PT
dc.description.versioninfo:eu-repo/semantics/publishedVersionpt_PT
dc.identifier.citationRodrigues, F., Teixeira, J., & Forte, P.* (2023). The reliability of the Timed-Up & Go test among Portuguese elderly. Healthcare, 11(7), 928. https://doi.org/10.3390/healthcare11070928pt_PT
dc.identifier.doi10.3390/healthcare11070928pt_PT
dc.identifier.issn2227-903
dc.identifier.urihttp://hdl.handle.net/10400.8/9975
dc.language.isoengpt_PT
dc.peerreviewedyespt_PT
dc.publisherMDPIpt_PT
dc.relationUID04045/2020pt_PT
dc.relation.publisherversionhttps://www.mdpi.com/2227-9032/11/7/928pt_PT
dc.rights.urihttp://creativecommons.org/licenses/by-nc-sa/4.0/pt_PT
dc.subjectOlder adultpt_PT
dc.subjectDynamic balancept_PT
dc.subjectReliabilitypt_PT
dc.subjectMeasurementpt_PT
dc.titleThe Reliability of the Timed Up and Go Test among Portuguese Elderlypt_PT
dc.typejournal article
dspace.entity.typePublication
oaire.citation.issue11pt_PT
oaire.citation.startPage928pt_PT
oaire.citation.titleHealthcarept_PT
oaire.citation.volume7pt_PT
person.familyNameRodrigues
person.givenNameFilipe
person.identifier613329
person.identifier.ciencia-id9B18-7FE1-74AF
person.identifier.orcid0000-0003-1327-8872
person.identifier.ridA-8152-2019
person.identifier.scopus-author-id57206270107
rcaap.rightsopenAccesspt_PT
rcaap.typearticlept_PT
relation.isAuthorOfPublication661e2126-79f7-445a-bda0-eb4c9d0bb0e2
relation.isAuthorOfPublication.latestForDiscovery661e2126-79f7-445a-bda0-eb4c9d0bb0e2

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
healthcare-11-00928-v2.pdf
Size:
255.61 KB
Format:
Adobe Portable Document Format
Description:
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.32 KB
Format:
Item-specific license agreed upon to submission
Description: