Objectives
The purpose of this study was to evaluate the effects of air polishing with sodium bicarbonate and erythritol powders on surface roughness and morphological changes in titanium abutments.
Methods
A total of 45 grade V titanium discs were divided in three groups: Group A (Control) air polished with air/water; Group B, air polished with sodium bicarbonate powder; and Group C, air polished with erythritol powder. After air polishing, the samples' roughness (Sa) in micrometres were analysed with an optical profilometer. The samples' surface morphology study was conducted via scanning electronic microscope (SEM). Data were described using mean and standard deviation of roughness values (Sa). Inferential analysis was performed using the ANOVA multiple comparison test followed by Tukey's post hoc test. Both tests used a 5% level of significance.
Results
After air polishing, average roughness of group A, B and C were 0.036, 0.046 and 0.037 μm, respectively, with statistically significant differences between groups A and B (p < 0.05). No statistically significant differences were found between group A and group C, as well as between group B and C (p > 0.05). As for the morphology analysis, damages to the titanium surface were only observed in group B.
Conclusions
The study indicates that air polishing with erythritol powder maintains titanium abutment integrity better than sodium bicarbonate, which increased surface roughness and caused damage. Erythritol is preferable for minimizing surface alterations and maintaining morphological stability.
Description
Acknowledgements
We would like to thank all the members of the Instituto Superior Técnico (IST Lisboa) who helped in the laboratorial part of this work.
Funding information
The authors declare no funds or financial support. EMS provided the materials but did not finance the study.
Journal Policy: Published - Option with associated OA fees, no embargo & CC BY licence - Locations: Any Website (including institutional repository): https://openpolicyfinder.jisc.ac.uk/id/publication/11881
Journal Policy: Published - Option with associated OA fees, no embargo & CC BY licence - Locations: Any Website (including institutional repository): https://openpolicyfinder.jisc.ac.uk/id/publication/11881
Keywords
Dental hygiene process of care Instrumentation Sonic Ultra sonic
Pedagogical Context
Citation
Roberto PFA, Luís HS, Oliveira SA. In vitro evaluation of surface roughness of titanium abutments after air polishing with different abrasive powders. Int J Dent Hygiene. 2024;00:1-7. doi:10.1111/idh.12838
Publisher
Wiley