A carregar...
3 resultados
Resultados da pesquisa
A mostrar 1 - 3 de 3
- Use of available phasor measurements for system observability: A case studyPublication . Vide, Paula Sofia Pita da Silva e Castro; Barbosa, F. P. Maciel; Ferreira, Isabel M.This paper proposes the use of available PMU measurements for establishing network observability. State estimation is an important EMS application for providing real time, reliable and qualitative information on the system state. The observability analysis is the necessary function of the whole network state estimation.This paper addresses the incorporation of PMU measurements with the purpose of full network observability. The methodology is validated by the results on IEEE 14, 30 and 57 bus test system.
- Performance metrics for evaluation of a mixed measurement based state estimatorPublication . Vide, P. Castro; Barbosa, F. Maciel; Carvalho, J. BelezaWith the development of synchronized phasor measurement technology in recent years, it gains great interest the use of PMU measurements to improve state estimation performances. In this paper, a mixed measurement (SCADA and PMU measurements) state estimator is proposed. Several measures useful for evaluating various aspects of the performance of the mixed measurement state estimator are proposed and explained. State Estimator validity, performance and characteristics of the results on IEEE 14 bus test system are presented.
- Metric Indices for Performance Evaluation of a Mixed Measurement based State EstimatorPublication . Vide, Paula Sofia; Barbosa, Fernando Pires Maciel; Carvalho, José António BelezaWith the development of synchronized phasor measurement technology in recent years, it gains great interest the use of PMU measurements to improve state estimation performances due to their synchronized characteristics and high data transmission speed The ability of the Phasor Measurement Units (PMU) to directly measure the system state is a key over SCADA measurement system. PMU measurements are superior to the conventional SCADA measurements in terms of resolution and accuracy. Since the majority of measurements in existing estimators are from conventional SCADA measurement system, it is hard to be fully replaced by PMUs in the near future so state estimators including both phasor and conventional SCADA measurements are being consideredIn this paper, a mixed measurement (SCADA and PMU measurements) state estimator is proposedSeveral useful measures for evaluating various aspects of the performance of the mixed measurement state estimator are proposed and explainedState Estimator validity, performance and characteristics of the results on IEEE 14 bus test system and IEEE 30 bus test system are presented.
