Name: | Description: | Size: | Format: | |
---|---|---|---|---|
The upgraded HADES inner TOF Wall will cover a total area of 8 m2 with 1116 variable-geometry 4-gap, symmetric, timing RPCs, readout by 2232 time and charge channels. Each RPC is individually shielded for robust multi-hit performance and optimum use of the readout channels (crosstalk minimization). The double layer configuration provides a useful degree of redundancy for very accurate timing of a large fraction of all particles crossing the detector. In this paper we describe the concept of the detector, its inner structure and the multi-hit performance. | 662.88 KB | Adobe PDF |
Advisor(s)
Abstract(s)
The upgraded HADES inner TOF Wall will cover a total area of 8 m2 with 1116 variable-geometry 4-gap, symmetric, timing RPCs, readout by 2232 time and charge channels. Each RPC is individually shielded for robust multi-hit performance and optimum use of the readout channels (crosstalk minimization). The double layer configuration provides a useful degree of redundancy for very accurate timing of a large fraction of all particles crossing the detector. In this paper we describe the concept of the detector, its inner structure and the multi-hit performance.
Description
Sousa, C. C. - Scopus ID: 35286184000 (Sousa, Carlos Manuel Pereira da Costa e)
Keywords
Crosstalk HADES Multi-hit RPC TOF
Citation
D. Belver, A. Blanco, P. Cabanelas, N. Carolino, E. Castro, J. Diaz, P. Fonte, J.A. Garzón, D. Gonzalez-Diaz, A. Gil, W. Koenig, L. Lopes, A. Mangiarotti, O. Oliveira, A. Pereira, C. Silva, C.C. Sousa, M. Zapata, The HADES RPC inner TOF wall, Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Volume 602, Issue 3, 2009, Pages 687-690, ISSN 0168-9002, https://doi.org/10.1016/j.nima.2008.12.090.
Publisher
Elsevier