Desenvolvimento e validação de um teste de força muscular em idosos: o Shoulder Flexion Test

datacite.subject.fosCiências Médicas::Ciências da Saúde
datacite.subject.sdg03:Saúde de Qualidade
dc.contributor.advisorRodrigues, Filipe Fernandes
dc.contributor.authorRodrigues, Alexandre Miguel Dias
dc.date.accessioned2026-08-03T14:30:30Z
dc.date.available2026-08-03T14:30:30Z
dc.date.issued2026-07-20
dc.description.abstractO presente estudo teve como objetivo central o desenvolvimento e a validação psicométrica de um novo instrumento para avaliar a resistência de força dos membros superiores em idosos, nomeadamente o Shoulder Flexion Test (SFT). Adotou-se um desenho observacional longitudinal com um intervalo de 16 semanas. A amostra final foi composta por 39 idosos (M = 83,82 anos). Avaliou-se a fiabilidade temporal e a validade concorrente, correlacionando o desempenho no SFT com o Arm Curl Test e a força de preensão manual. Os resultados demonstraram que o SFT apresenta uma fiabilidade temporal moderada a boa, com um ICC de 0,664 (medidas únicas) e 0,790 (medidas médias). O teste t de amostras emparelhadas não revelou diferenças significativas entre avaliações (p = 0,384), e a análise de Bland-Altman confirmou elevada concordância, com 94,8% dos sujeitos dentro dos limites estipulados e um viés médio reduzido de 0,41 repetições. Verificou-se uma validade concorrente robusta, com correlações fortes com o Arm Curl (r = 0,71) e moderadas com a dinamometria (r = 0,42 a 0,50). Conclui-se que o SFT apresenta propriedades psicométricas adequadas, assumindo-se como uma ferramenta ecológica, padronizada para o sistema métrico e economicamente acessível para a monitorização rigorosa do declínio funcional em contextos geriátricospor
dc.description.abstractThe main objective of this study was the development and psychometric validation of a new tool to assess upper limb muscle endurance in older adults: the Shoulder Flexion Test (SFT). A longitudinal observational design with a 16-week interval was adopted. The final sample consisted of 39 older adults (M = 83.82 years). Temporal reliability and concurrent validity were assessed by correlating the SFT performance with the Arm Curl Test and handgrip strength. The results demonstrated that the SFT has moderate to good temporal reliability, with an ICC of 0.664 (single measures) and 0.790 (average measures). The paired t-test revealed no significant differences between assessments (p = 0.384), and the Bland-Altman analysis confirmed high agreement, with 94.8% of subjects within the limits and a small mean bias of 0.41 repetitions. Robust concurrent validity was observed, showing strong correlations with the Arm Curl (r = 0.71) and moderate correlations with handgrip dynamometry (r = 0.42 to 0.50). In conclusion, the SFT presents adequate psychometric properties, serving as an ecological, metric-system-based, and cost-effective tool for the rigorous monitoring of functional decline in geriatric contexts.eng
dc.identifier.tid204335876
dc.identifier.urihttp://hdl.handle.net/10400.8/16680
dc.language.isopor
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/
dc.subjectAvaliação funcional
dc.subjectEnvelhecimento
dc.subjectFiabilidade
dc.subjectForça muscular
dc.subjectIdosos
dc.subjectValidade
dc.subjectAging
dc.subjectFunctional assessment
dc.subjectMuscle strength
dc.subjectOlder adults
dc.subjectReliability
dc.subjectValidity
dc.titleDesenvolvimento e validação de um teste de força muscular em idosos: o Shoulder Flexion Test
dc.typemaster thesis
dspace.entity.typePublication
thesis.degree.nameMestrado em Prescrição do Exercício e Promoção da Saúde

Ficheiros

Principais
A mostrar 1 - 1 de 1
Miniatura indisponível
Nome:
Dissertação_Alexandre_Rodrigues.pdf
Tamanho:
485.26 KB
Formato:
Adobe Portable Document Format
Licença
A mostrar 1 - 1 de 1
Miniatura indisponível
Nome:
license.txt
Tamanho:
1.32 KB
Formato:
Item-specific license agreed upon to submission
Descrição: