INESCC-DL - Resumos em Livros de Actas
Permanent URI for this collection
Browse
Browsing INESCC-DL - Resumos em Livros de Actas by Field of Science and Technology (FOS) "Ciências Naturais::Ciências da Computação e da Informação"
Now showing 1 - 2 of 2
Results Per Page
Sort Options
- Assessing the influence of uncertainty in land cover mapping and digital elevation models on flood risk mappingPublication . Gonçalves, Luísa M.S.; Fonte, Cidália C.; Gomes, RicardoThis paper proposes an approach to assess the influence of the uncertainty present in the parameters dependent on the land cover and elevation data over the peak flow values and the subsequent delineation of flooded areas. The proposed approach was applied to produce vulnerability and risk maps that integrate uncertainty for the urban area of Leiria, Portugal. A SPOT-4 satellite image and DEMs of the region were used. The peak flow was computed using the Soil Conservation Service method and HECHMS, HEC-RAS, Matlab and ArcGIS software programs were used. The analysis of the results obtained for the presented case study enables the identification of the order of magnitude of uncertainty associated to the watershed peak flow value and the identification of the areas which are more susceptible to flood risk to be identified.
- Indoor air quality audit in two office buildings in PortugalPublication . Ramos, Joao; Pinto, FernandoThe indoor air quality that a building presents is not always from our knowledge. In fact, we may find ourselves exposed to an indoor air which can be harmful to human health, affecting the quality of life and productivity, which also will have economic repercussions at this level. Given the Portuguese law for energy and indoor air quality (IAQ) certification of large service buildings, the indoor air quality requirements were here presented and, in addition, this paper provides an overview of the current Portuguese IAQ technical procedures to audit existent buildings. It was also intended with this study to evaluate the indoor air quality experienced by the occupants of two office buildings, an old and a recent, with the same activity and occupancy, without air-conditioning systems, where were carried out indoor air quality characterizations and, in particular, have been assessed the CO2 concentration and the typical renewal air exchange rates in different zones of the buildings, as a ventilation effectiveness monitoring. During the building's regular occupancy period, the authors have been done monitoring campaigns, which took place in winter and summer seasons. They have been detected that the values of some parameters under review were non-compliance situations in winter, in contrast with the summer due to the increase of ventilation promoted by the occupants taking advantage of the favourable conditions of the Mediterranean weather. Consequently, the proposed IAQ audit approach may be helpful to characterize indoor air pollutants, to evaluate the ventilation effectiveness and to correlate it with the indoor air quality perception and self-control actions of the occupants.