Browsing by Issue Date, starting with "2018-11-22"
Now showing 1 - 3 of 3
Results Per Page
Sort Options
- Comparative study on the seismic performance assessment of existing buildings with and without retrofit strategiePublication . Rakesh, Dumaru; Rodrigues, Hugo; Varum, HumbertoA large number of inflled RC frame buildings have undergone moderate to extensive structural damages and even collapsed after the 2015 Gorkha earthquake. The repair and maintenance works are still being carried out in the existing RC buildings, many of them without any consultation with design engineers. Such practices are likely to create a beneft of doubt on the efciency of the retroftting works and repair/maintenance works. Therefore, the present study aims to evaluate the seismic performance of the existing non- and pre-engineered buildings, and later employed retroft measures that are commonly practised in the region. The analytical results revealed that the selected buildings were seismically defcient and are most likely to undergo extensive damage to collapse states, at 0.3 g PGA. It was found that the retroft measure signifcantly enhances the stifness, maximum strength and ductility in the existing buildings. The pushover curves indicated that the steel bracing highly increased the stifness, strength and ductility capacity in all case study buildings. The steel-braced building was recorded to have increased the maximum base shear capacity by almost ten times for the soft-storey MRT1 building. Similarly, the retroft measures also eliminated the potential single storey drift concentration recorded in the original building, such that a uniform inter-storey drift profle can be attained throughout. The conditional probability of collapse for the case study buildings, at 0.3 g PGA, ranges from 13.5 to 42% and could be minimized below 4% in the worst case scenario for the shear wall. All the numerical results demonstrated that steel bracing was much more efective in enhancing the seismic performance of the existing buildings.
- Collecting Information about Air Quality using SmartphonesPublication . Pereira, André; Patrício, Beatriz; Fonte, Filipa; Marques, Sandro; Reis, Catarina I.; Maximiano, MarisaNowadays, one of the major public health concerns is the quality of the air that surrounds us and knowing how polluted it might be. To compute the Air Quality Index for a specific geographical site, five pollutants can be considered: particulate matter (PM2.5 and PM10), ground-level Ozone (O3), Nitrogen dioxide (NO2) and Sulphur dioxide (SO2). If we consider the data from both atmospheric conditions and the existence of catastrophic events, we will be able to cross it with existing data from sensor nodes (gathering air pollutants’ data) in order to accomplish a more detailed understanding of the current air quality in a specific area. Our solution introduces a differentiating factor: the concept of turning every smartphone into a dynamic sensor node that can be used to actively contribute to the centralized platform that gathers all the data from the sensor nodes. This feature enables citizens to play a significant and empowering role regarding healthcare conditions. The proposed system integrates several modules including a Custom Delivery Solution (CDS), and, as an alternative, an out-of-the-box solution named ThingSpeak. Both solutions offer a service delivery system to the mobile app that presents the latest data to the users and allows them to submit their own data.
- Simulação do desempenho energético com base na metodologia BIM: caso de estudo do edifício da ESSLeiPublication . Henschel, Larissa Sibille; Gonçalves , Luísa Maria Silva; Bernardo, Hermano Joaquim dos SantosO setor da construção contribui de forma significativa para o consumo total de energia e, este é um dos motivos que faz com que cada vez mais sejam exigidas medidas de eficiência energética nas edificações. Existem inúmeros programas que proporcionam a simulação do desempenho energético de edifícios e, com seu uso, é possível comparar diferentes alternativas de projeto a fim de decidir pela melhor delas. Building Information Modelling (BIM) é uma metodologia que é cada vez mais utilizada nas empresas de construção em virtude das facilidades que proporciona, porém as suas funcionalidades ainda não estão exploradas na sua totalidade pelos profissionais. Assim, no que diz respeito ao estudo do consumo de energia de edifícios, existe a necessidade de se conhecer melhor a interação e o potencial quer das ferramentas de simulação energética neste ambiente, quer das informações integradas no modelo. A presente dissertação apresenta um estudo energético de um dos edifícios do Instituto Politécnico de Leiria desenvolvido em ambiente BIM. A partir do modelo 3D desenvolvido, foram feitas configurações para a criação e validação do modelo energético para a posterior realização de simulações energéticas através do Energy Analysis do Autodesk Revit, que usa o mecanismo do Autodesk Green Building Studio. Foi ainda analisada a interoperabilidade entre os softwares, assim como a eficiência e fiabilidade dos resultados da simulação, através da comparação dos resultados obtidos com o real consumo de energia do edifício, o qual é conhecido a partir de dados de uma auditoria energética. Os resultados também foram comparados com os obtidos com um estudo efectuado por Santos (2012), onde foi utilizado o software EnergyPlus. Assim, foi possível concluir que o uso do Energy Analysis juntamente com o Green Building Studio proporciona uma interface amigável e um uso facilitado, contudo com algumas limitações nomeadamente na alteração dos padrões predefinidos. A simulação também apresenta uma grande gama de resultados, como por exemplo o potencial de economia de energia, cargas de aquecimento e arrefecimento, e rosa dos ventos, dados que foram também explorados ao longo do estudo.