Calibration of mirror position and extrinsic parameters in axial non-central catadioptric systems
| datacite.subject.fos | Engenharia e Tecnologia::Engenharia Eletrotécnica, Eletrónica e Informática | |
| datacite.subject.sdg | 03:Saúde de Qualidade | |
| datacite.subject.sdg | 07:Energias Renováveis e Acessíveis | |
| datacite.subject.sdg | 11:Cidades e Comunidades Sustentáveis | |
| dc.contributor.author | Perdigoto, Luís | |
| dc.contributor.author | Araujo, Helder | |
| dc.date.accessioned | 2026-03-12T19:20:38Z | |
| dc.date.available | 2026-03-12T19:20:38Z | |
| dc.date.issued | 2013-08 | |
| dc.description.abstract | We propose a novel calibration method for catadioptric systems made up of an axial symmetrical mirror and a pinhole camera with its optical center located at the mirror axis. The calibration estimates the relative camera/mirror position and the extrinsic rotation and translation w.r.t. the world frame. The procedure requires a single image of a (possibly planar) calibration object. We show how most of the calibration parameters can be estimated using linear methods (Direct-Linear-Transformation algorithm) and cross-ratio. Two remaining parameters are obtained by using non-linear optimization. We present experimental results on simulated and real images. | eng |
| dc.identifier.citation | Luis Perdigoto, Helder Araujo, Calibration of mirror position and extrinsic parameters in axial non-central catadioptric systems, Computer Vision and Image Understanding, Volume 117, Issue 8, 2013, Pages 909-921, ISSN 1077-3142, https://doi.org/10.1016/j.cviu.2013.04.001. | |
| dc.identifier.doi | 10.1016/j.cviu.2013.04.001 | |
| dc.identifier.issn | 1077-3142 | |
| dc.identifier.uri | http://hdl.handle.net/10400.8/15863 | |
| dc.language.iso | eng | |
| dc.peerreviewed | yes | |
| dc.publisher | Elsevier | |
| dc.relation.hasversion | https://www.sciencedirect.com/science/article/pii/S1077314213000635?via%3Dihub | |
| dc.relation.ispartof | Computer Vision and Image Understanding | |
| dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | |
| dc.subject | Non-central catadioptric vision systems | |
| dc.subject | Calibration | |
| dc.subject | Axial symmetric mirrors | |
| dc.title | Calibration of mirror position and extrinsic parameters in axial non-central catadioptric systems | eng |
| dc.type | journal article | |
| dspace.entity.type | Publication | |
| oaire.citation.endPage | 921 | |
| oaire.citation.issue | 8 | |
| oaire.citation.startPage | 909 | |
| oaire.citation.title | Computer Vision and Image Understanding | |
| oaire.citation.volume | 117 | |
| oaire.version | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |
| person.familyName | Perdigoto | |
| person.givenName | Luis | |
| person.identifier.orcid | 0000-0002-2626-3154 | |
| relation.isAuthorOfPublication | 21974cb3-96e9-4071-bbd1-149f86160821 | |
| relation.isAuthorOfPublication.latestForDiscovery | 21974cb3-96e9-4071-bbd1-149f86160821 |
Ficheiros
Principais
1 - 1 de 1
Miniatura indisponível
- Nome:
- Calibration of mirror position and extrinsic parameters in axial non-central.pdf
- Tamanho:
- 1.69 MB
- Formato:
- Adobe Portable Document Format
Licença
1 - 1 de 1
Miniatura indisponível
- Nome:
- license.txt
- Tamanho:
- 1.32 KB
- Formato:
- Item-specific license agreed upon to submission
- Descrição: