Repository logo
 
Loading...
Thumbnail Image
Publication

Quasistatic and fatigue behavior of an AISI H13 steel obtained by additive manufacturing and conventional method

Use this identifier to reference this record.
Name:Description:Size:Format: 
Quasistatic and fatigue behavior of an AISI H13 steel obtained by additive manufacturing and conventional method.pdfThis work aims to compare the mechanical behavior of an AISI H13 steel obtained by additive manufacturing with that obtained by conventional manufacturing methods. The average values of the ultimate tensile strength (UTS) and ductility obtained for the specimens produced by the conventional method were equal to 658 MPa and 18%, respectively, which compares with 503 MPa and 0.75% registered for the selective laser melting (SLM) specimens. Inversely, the average hardness value determined for the SLM specimens was higher, 450 HV, than the observed for the conventional, 200 HV. In addition, the maximum applied stress corresponding to a fatigue limit's endurance of 2 × 106 cycles was equal to 340 and 85 MPa for conventional and SLM specimens, respectively. Therefore, from a fatigue design point of view, it was possible to infer that σmax/UTS = 0.17 for the SLM specimens tested. Porosity and lack of fusion influenced the static and the fatigue strength negatively in the SLM specimens.34.52 MBAdobe PDF Download

Advisor(s)

Abstract(s)

This work aims to compare the mechanical behavior of an AISI H13 steel obtained by additive manufacturing with that obtained by conventional manufacturing methods. The average values of the ultimate tensile strength (UTS) and ductility obtained for the specimens produced by the conventional method were equal to 658 MPa and 18%, respectively, which compares with 503 MPa and 0.75% registered for the selective laser melting (SLM) specimens. Inversely, the average hardness value determined for the SLM specimens was higher, 450 HV, than the observed for the conventional, 200 HV. In addition, the maximum applied stress corresponding to a fatigue limit's endurance of 2 × 106 cycles was equal to 340 and 85 MPa for conventional and SLM specimens, respectively. Therefore, from a fatigue design point of view, it was possible to infer that σmax/UTS = 0.17 for the SLM specimens tested. Porosity and lack of fusion influenced the static and the fatigue strength negatively in the SLM specimens.

Description

Fonte: https://www.researchgate.net/publication/354026591_Quasistatic_and_fatigue_behavior_of_an_AISI_H13_steel_obtained_by_additive_manufacturing_and_conventional_method

Keywords

AISI H13 mechanical properties powder bed fusion selective laser melting (SLM)

Pedagogical Context

Citation

Garcias JF, Martins RF, Branco R, et al. Quasistatic and fatigue behavior of an AISI H13 steel obtained by additive manufacturing and conventional method. Fatigue Fract Eng Mater Struct. 2021; 44(12): 3384-3398. doi: https://doi.org/10.1111/ffe.13565.

Organizational Units

Journal Issue