Logo do repositório
 
A carregar...
Miniatura
Publicação

The partial average power as a fault diagnostic parameter applied to SRM drives

Utilize este identificador para referenciar este registo.
Nome:Descrição:Tamanho:Formato: 
The partial average power as a fault diagnostic parameter applied to SRM drives.pdfA new fault diagnostic parameter, applied to switched reluctance motor drives, is presented. The proposed parameter is a partial average power based on the power converter supply current and the rotor mechanical position information. At high speed operating conditions phase current is not regulated and the machine closed-loop control only needs to observe one current, which is the power converter supply current, in order to avoid excessive current amplitudes. The adopted control strategy is clearly explained. Several simulation results are presented and discussed considering different operating conditions. The normal operation, a fault occurrence in a power switch and a sudden mechanical load decrease are analysed. The simulation results permit to validate the proposed partial average power as an appropriate parameter for the diagnosis of an open-circuit fault in a power switch.460.51 KBAdobe PDF Ver/Abrir

Orientador(es)

Resumo(s)

A new fault diagnostic parameter, applied to switched reluctance motor drives, is presented. The proposed parameter is a partial average power based on the power converter supply current and the rotor mechanical position information. At high speed operating conditions phase current is not regulated and the machine closed-loop control only needs to observe one current, which is the power converter supply current, in order to avoid excessive current amplitudes. The adopted control strategy is clearly explained. Several simulation results are presented and discussed considering different operating conditions. The normal operation, a fault occurrence in a power switch and a sudden mechanical load decrease are analysed. The simulation results permit to validate the proposed partial average power as an appropriate parameter for the diagnosis of an open-circuit fault in a power switch.

Descrição

Article number 5414708 - 35th Annual Conference of the IEEE Industrial Electronics Society, IECON 20093 November 2009 through 5 November 2009 - Code 79912

Palavras-chave

Reluctance motors Reluctance machines Rotors Current supplies Power supplies Drives Fault tolerance Circuit faults Stators Mining industry

Contexto Educativo

Citação

N. S. Gameiro and A. J. M. Cardoso, "The partial average power as a fault diagnostic parameter applied to SRM drives," 2009 35th Annual Conference of IEEE Industrial Electronics, Porto, Portugal, 2009, pp. 1356-1361, doi: https://doi.org/10.1109/IECON.2009.5414708.

Projetos de investigação

Unidades organizacionais

Fascículo

Editora

IEEE Canada

Licença CC

Sem licença CC

Métricas Alternativas