Repository logo
 
Publication

Fit accuracy of removable partial denture metal frameworks produced by CAD-CAM – a clinical study

dc.contributor.authorConceição, Pedro R.
dc.contributor.authorFranco, Margarida Cabrita
dc.contributor.authorAlves, Nuno
dc.contributor.authorPortugal, Jaime
dc.contributor.authorNeves, Cristina B.
dc.date.accessioned2023-04-17T14:07:41Z
dc.date.available2023-04-17T14:07:41Z
dc.date.issued2021-12-23
dc.description.abstractObjectives: To assess the effect of a CAD-CAM protocol fabrication on the clinical fit accuracy of removable partial denture metal frameworks to abutment teeth. Methods: Fifteen patients with partial edentulism were selected to participate in this clinical study, and twenty dental arch rehabilitations were planned. For each dental arch (n=20), two cobalt-chromium frameworks were produced through two protocols: CAD-CAM production (experimental group); and conventional lost-wax casting technique (control group). Clinical fit accuracy was assessed using an indirect quantitative method to evaluate the gap between the framework occlusal rest and the corresponding rest seat. A silicone mold of that gap was obtained, digitized, and analyzed by micro-computed tomography. The two silicone molds obtained for each occlusal rest were overlapped and evaluated for thickness and volume. Data were analyzed with the paired t test for silicone thickness results and the Wilcoxon test for silicone volume results (α= 0.05). Results: Considering the two dependent variables under study, no statistically significant (p=0.441 for silicone thickness and p=0.204 for silicone volume) differences were found between groups. Conclusions: The results of this study suggest that the CAD-CAM protocol applied is a viable method for the production of removable partial denture metal frameworks.pt_PT
dc.description.versioninfo:eu-repo/semantics/publishedVersionpt_PT
dc.identifier.doi10.24873/j.rpemd.2021.12.851pt_PT
dc.identifier.issn1646-2890
dc.identifier.urihttp://hdl.handle.net/10400.8/8394
dc.language.isoengpt_PT
dc.peerreviewedyespt_PT
dc.publisherSPEMDpt_PT
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/pt_PT
dc.titleFit accuracy of removable partial denture metal frameworks produced by CAD-CAM – a clinical studypt_PT
dc.title.alternativeAdaptação de esqueletos metálicos de próteses parciais removíveis produzidos por CAD-CAM – estudo clínicopt_PT
dc.typejournal article
dspace.entity.typePublication
oaire.citation.titleRevista Portuguesa de Estomatologia, Medicina Dentária e Cirurgia Maxilofacialpt_PT
oaire.citation.volumeVol. 62, n.º 4pt_PT
person.familyNameFranco
person.familyNameAlves
person.givenNameMargarida
person.givenNameNuno
person.identifier2300879
person.identifier452149
person.identifier.ciencia-id3818-262C-0441
person.identifier.ciencia-id311E-1559-8F6C
person.identifier.orcid0000-0001-9659-7646
person.identifier.orcid0000-0002-5016-0868
person.identifier.ridN-4073-2013
person.identifier.scopus-author-id55885992900
person.identifier.scopus-author-id7006403383
rcaap.rightsopenAccesspt_PT
rcaap.typearticlept_PT
relation.isAuthorOfPublication7235dc45-1d20-4fd5-a691-9c474b73b6f4
relation.isAuthorOfPublicationbbd46a74-b77e-4539-a5fe-62ee95cdc4fa
relation.isAuthorOfPublication.latestForDiscovery7235dc45-1d20-4fd5-a691-9c474b73b6f4

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
1_19_61cdfed43e5b2.pdf
Size:
592.02 KB
Format:
Adobe Portable Document Format
Description:
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.32 KB
Format:
Item-specific license agreed upon to submission
Description: